Abbott Rapid Diagnostics × McKesson — point-of-care diagnostics
A compact, rapid, multi-assay analyzer that puts HbA1c, lipid, ACR, and CRP results in the clinician's hands in minutes — no lab send-out, no tracking down results. HbA1c in about three minutes, NGSP and IFCC certified. A new-customer program runs through December 31, 2026 — ask your account team for options.
Multiple analytes on one instrument, an all-in-one test cartridge, and no calibration or maintenance — built for near-patient testing at the point of care.
Quantitative HbA1c, Lipid Panel, ACR, and CRP — screening, management, and monitoring across diabetes, cardiovascular, kidney, and respiratory disease.
Each cartridge holds an integrated sample collection device and all reagents for a single test. Factory calibration is read from the lot barcode by the integrated camera; self-check systems catch errors automatically.
3.4 kg with a color touch display. The optional battery kit (1117292) runs up to 10 hours — about 60 tests — for mobile units, home visits, and nursing homes; carry bag B5592.
| HbA1c test facts | Afinion™ HbA1c |
|---|---|
| Time to result | ~3 minutes |
| Sample | 1.5 µL; capillary and venous whole blood |
| Measuring range | 4%–15% HbA1c (20–140 mmol/mol) |
| Storage | 3 months at room temperature |
| Controls | Ready-to-use, two levels |
| Certification | NGSP and IFCC certified |
| Interference | No interference from common Hb variants |
| Analyzer specifications | Afinion™ 2 |
|---|---|
| Assays | HbA1c, Lipid Panel, ACR, CRP — four tests on one platform |
| Size / weight | 20 cm × 19 cm × 33 cm · 3.4 kg |
| Display | Color touch display |
| Connectivity | POCT1-A, HL7, ASTM 1381-85 / 1394-97 over TCP/IP; USB for barcode reader and printer |
| Calibration / maintenance | None required — lot calibration read from cartridge barcode |
| Quality control | QC and operator lockout; integrated failsafe self-check |
Sources: Abbott Afinion 2 product page and Afinion HbA1c sell sheet (© 2025 Abbott, RDx-25001512-01). FDA clearances: K214117 (HbA1c on Afinion 2, 2023-09-27), K171650 (HbA1c and ACR on Afinion 2, 2017-11-21), K182988 (HbA1c Dx on Afinion 2, 2018-11-29), K132031 (lipid panel, 2014), K072409 (ACR, 2008) — accessdata.fda.gov 510(k) database.
"Point-of-care HbA1c testing represents an opportunity for improved care of people with diabetes." — Egbunike & Gerard, Diabetes Educator 2013. "Point-of-care testing for HbA1c provides the opportunity for more timely treatment changes." — ADA, Diabetes Care 2018.
Cited on Abbott's Afinion HbA1c sell sheet.
Rapid A1c availability improves clinical decision-making (Diabetes Care 2003); point-of-care testing improves patient satisfaction in general practice (Br J Gen Pract 2010) and implementation is established in ambulatory practice (Am J Clin Pathol 2014).
References as listed on Abbott's sell sheet.
Point-of-care tests bill on the Medicare Clinical Laboratory Fee Schedule. National amounts below are from the CY 2026 Q4 file.
| Code | CMS descriptor | National rate |
|---|---|---|
| 83036 | Hemoglobin A1C level | $9.71 |
| 82044 | Urine microalbumin (protein) analysis | $6.23 |
| 82570 | Creatinine level (kidney function) | $5.18 |
| 80061 | Blood test, lipids (cholesterol and triglycerides) | $13.39 |
| 86140 | C-reactive protein, detection of infection or inflammation | $5.18 |
| 86141 | C-reactive protein, high-sensitivity | $12.95 |
Source: CMS Clinical Laboratory Fee Schedule Public Use File, CY 2026 Q4 (PUF_CLFS_CY2026_Q4V1), retrieved 2026-11-23.
Contact named in the source materials.
McKesson Medical-Surgical